A reducer can also be used either as a nozzle or diffuser, depending on the mach number of the flow. Dielectric unions, with dielectric insulation, separate dissimilar metals to prevent galvanic corrosion. When two dissimilar metals are in contact with an electrically conductive solution , they form an electrochemical couple which generates a voltage by electrolysis. When the metals are in direct contact with each other, the electric current from one to the other also moves metallic ions from one to the other; this dissolves one metal, depositing it on the other. A dielectric union breaks the electrical path with a plastic liner between its halves, limiting galvanic corrosion.

Isolation valves are typically left in either a fully open or fully closed position. A given isolation valve may be in place for many years without being operated, but must be designed to be readily operable whenever needed, including emergency use. Since the alignment stop is missing, it is up to the installer to carefully measure the final location of the slip coupling to ensure that it is located correctly. If there’s a pipe needing cut or bent, we have the equipment to help make it happen.

We maintain deep inventories of stainless steel fittings to provide quick shipments. These disadvantages are less problematic for fire sprinkler installations, because standing water in the steel pipes does not flow, except during occasional tests or actual activation by a fire. The introduction of oxygen dissolved in fresh supplies of water will cause some corrosion, but this soon stops in the absence of any source of further water-borne oxygen. Threaded steel pipe is widely used in buildings to convey natural gas or propane fuel, and is also a popular choice in fire sprinkler systems due to its resistance to mechanical damage and high heat .

With high peak-flow volumes, the design and construction of these systems may resemble those of storm sewers. Never let that be the case with our selection of copper tubes, stainless steel tubes and different plastic pipe options. Long radius pipeline bends are used in fluid transportation lines which required pigging. Due to their long radius and smooth change of direction, the pipe bend has very less pressure drop, and a smooth flow of fluid & pig is possible.

galvanised malleable iron pipe fittings

Increase the length or join solvent weld pipe together with Magicflex solvent elbows and connectors from Wirquin. All our solvent weld connectors can bend and stay fixed when welded. Spend over £25 online and receive free delivery with your order or click and collect from your closest Toolstation branch. When compared to other connection types, press fittings have the advantages of installation speed and safety. Pressing a stainless steel fitting can be completed within 5 seconds with the correct equipment.

The pressure losses that inevitably occur in pipeline systems can be recorded either by measuring equipment or by calculation. In order to achieve an optimum seal, conical screw-in threads must be provided with an additional sealing means, e.g., Teflon tape. Flare fittings were originally developed for high pressure applications and are used widely in locations that are exposed to strong vibrations. As the cutting ring moves along a precisely de ned assembly path, its cutting edges are forced into the surface of the hydraulic pipe.

Elbows are generally available with an angle of 22.5o, 45o and 90o. If pipes are of same diameter then normal elbows are used otherwise Reducer elbows are used. These are generally coming with female threads and we can fix them by butt or socket welding also. Obviously, pipe fittings are attached to the end of pipes that allow them to change direction, control the flow, and change the diameter of the pipe. Being a non-trivial part of plumbing and piping systems, consulting us with your need is definitely advised to save yourself time, money, materials, and headaches. Unions are used as an alternative to flanges connection in low-pressure small bore piping where the dismantling of the pipe is required more often.